| | | | 0009801 | | |
| minor | | 2025-07-07 | Inconsistency in Machinery/ProcessValues NodeSet in ProcessValueType |
| | | | 0009868 | 1 | |
| tweak | | 2025-07-07 | Example of use of MaterialUse is UpperCase in ISA95 it is lowerCase |
| | | | 0010336 | 2 | |
| minor | | 2025-07-07 | Missing Conformance Units in NodeSet (Machinery Result-Transfer) |
| | | | 0009461 | 2 | |
| minor | | 2025-07-07 | typo in Annex C - RPI <-> PRI |
| | | | 0008635 | 3 | |
| minor | | 2025-07-07 | Machinery never actually defines the MachineryBuildingBlocks Object. |
| | | | 0010419 | | |
| minor | new | 2025-07-07 | Small issues in UaNodeSet |
| | | | 0009794 | 1 | |
| minor | | 2025-07-05 | Base Info Server Capabilities 006 produces a rendom string that very often containes '$'-character. |
| | | | 0010415 | | |
| minor | | 2025-07-05 | Username Password / 006 needs to expect BadUserIdentityTokenInvalid |
| | | | 0010416 | | |
| minor | | 2025-07-05 | Certificate generation fails because wmic is no longer available in Windows 11 |
| | | | 0010417 | | |
| minor | | 2025-07-05 | Adding further UAFX Test Cases |
| | | | 0010418 | | |
| minor | | 2025-07-05 | Update test cases to 1.03.09.505 |
| | | | 0010374 | 1 | |
| minor | | 2025-07-04 | Rework test scripts for InputData and OutputData folders |
| | | | 0010407 | 1 | |
| crash | | 2025-07-04 | Allocation error in CttReadValueIdsPrivate does not trigger Resource Cleanup |
| | | | 0010412 | 1 | |
| major | | 2025-07-03 | Security User Name Password / 006: Testscript appends ServerNonce |
| | | | 0010324 | 1 | |
| minor | | 2025-07-03 | "History > Historical Access Read Raw > 013.js" expect certain minimum lengths for array dimensions |
| | | | 0010325 | | |
| minor | | 2025-07-03 | "History > Historical Access Read Raw > Err-016.js" expects service level code |
| | | | 0010361 | 1 | |
| minor | | 2025-07-03 | Add mapping for units defined in IEC 62720 |
| | | | 0010328 | 1 | 1 |
| minor | | 2025-07-03 | Should Attribute Write Values 006 accept BadOutOfRange? |
| | | | 0010380 | | |
| minor | | 2025-07-03 | Create Test Case for unknown optional certificate fields and flags |
| | | | 0010054 | 2 | 3 |
| minor | | 2025-07-03 | Base Information - Base Info Type System - ReferenceTypesValidation.js |
| | | | 0010409 | 3 | |
| minor | | 2025-07-03 | Subscription Durable - 005.js always report error |
| | | | 0010410 | 1 | |
| minor | | 2025-07-03 | SubscriptionDurable - Err-004.js |
| | | | 0010402 | 1 | |
| minor | | 2025-07-03 | Base Info EngineeringUnits / 001: ExpectedResults need to be extended |
| | | | 0010401 | 1 | |
| minor | | 2025-07-03 | Base Info EngineeringUnits / 001: ExpectedResults need to be extended |
| | | | 0010405 | 1 | |
| minor | | 2025-07-03 | CTT needs to limit the number of configured MonitoredItems |
| | | | 0010400 | 1 | |
| tweak | | 2025-07-03 | Base Info Currency needs to be skipped if no instance can be found |
| | | | 0010399 | 1 | |
| minor | | 2025-07-03 | update ConformanceUnit DI DeviceHealthProperty |
| | | | 0010411 | 1 | |
| minor | | 2025-07-02 | PROFIenergy: StartPause method argument name different in document and Nodeset |
| | | | 0009784 | 2 | |
| minor | | 2025-07-02 | ConformanceUnits needed that state everything defined in the Descriptor is exposed in the Server |
| | | | 0010273 | 1 | |
| minor | | 2025-07-01 | Inconsistency between Json and Uadp PubSubConnection discovery messages |
| | | | 0010398 | 1 | |
| feature | new | 2025-06-28 | Add additional CU for each AlarmTYpe |
| | | | 0010396 | | |
| minor | new | 2025-06-26 | DHCP client feature should be a Conformance Unit for the Controller profile and appear in Part 84 |
| | | | 0010395 | | |
| minor | new | 2025-06-25 | Issues with NodeSet File |
| | | | 0010386 | | |
| minor | new | 2025-06-25 | Invalid syntax of the example model - Figure 7 |
| | | | 0004411 | 1 | |
1.04 | minor | | 2025-06-25 | Error when supporting security policy that CTT does not support |
| | | | 0010379 | 1 | 1 |
| major | | 2025-06-23 | Init for the History Read Raw CUs tries to read data from "start of time" |
| | | | 0010356 | 1 | |
1.05.05 RC2 | text | | 2025-06-17 | Clarification about a “shall” in Part 21 / Chapter 5.3 Composite Identity / last paragraph / last sentence |
| | | | 0010310 | 2 | |
| minor | new | 2025-06-13 | AliasName Client Base - should it be mandatory from the beginning? |
| | | | 0010016 | 2 | |
| minor | | 2025-06-13 | Clarification - ClientUserId for X509IdentityToken |
| | | | 0010351 | 1 | |
| block | | 2025-06-10 | Calling UaStructureDefinition.fromTypeNodeId() may result in an infinite loop |
| | | | 0010237 | 2 | |
| minor | | 2025-06-05 | JWT 'sub' cannot be mapped to a Role |
| | | | 0010196 | 2 | |
| minor | new | 2025-06-04 | Alarm and Conditions tests should not use CallMethod response timestamp as expected Event Time minimum |
| | | | 0009178 | | |
| block | | 2025-06-03 | NodeSetUtility: GetDataType() does not work for all DataTypes |
| | | | 0010358 | 2 | |
| major | | 2025-06-02 | Deprecate Query Services |
| | | | 0005384 | 1 | |
| minor | | 2025-06-02 | Add a mapping for CloudEvents |
| | | | 0009985 | | |
| minor | | 2025-05-31 | Base Info ResendData Method 010.js writes several values to the same variable - but expects only one change |
| | | | 0010347 | | |
| minor | | 2025-05-31 | Better support for interface class testing |
| | | | 0010350 | 1 | |
| minor | | 2025-05-31 | Check for vendor specific nodes in namespace 0 |
| | | | 0010349 | | |
| minor | | 2025-05-30 | Check for SDK artefacts |
| | | | 0009037 | 3 | |
| minor | | 2025-05-30 | CTT needs a user with admin permissions to check diagnostic nodes |